home *** CD-ROM | disk | FTP | other *** search
/ Power Tools 1993 October - Disc 1 / Power Tools (Disc 1)(October 1993)(HP).iso / spec / a3821248 / a3821248.txt < prev    next >
Text File  |  1992-05-09  |  7KB  |  161 lines

  1. HP-IB* Interface for HP 3000 Series 900 Computer Systems, Technical
  2. Data
  3.    For HP 3000 Series 900 Computer Systems Product Number 27113A
  4. The HP 27113A HP-IB* Interface allows connection of up to 14
  5. HP-IB-compatible devices to HP 3000 Series 900 systems that use the
  6. Channel I/O (CIO) backplane. HP-IB compatible devices include flexible
  7. and hard disks, printers, plotters, magnetic tape devices, graphics
  8. digitizers, and an extensive list of instruments.
  9.  
  10. Features
  11. o 980 Kbytes/s high-speed, 500 Kbytes/s standard-speed
  12. o Fully IEEE-488-1978 compatible
  13. o Onboard intelligence off-loads the host computer, leaving more CPU
  14.   resources for application-oriented tasks
  15. o Support of up to 14 standard devices, 8 high-speed devices
  16. * The Hewlett-Packard Interface Bus (HP-IB) is HP's implementation of
  17. IEEE Standard 488-1978:  "Digital Interface for programmable
  18. Instrumentation" and identical ANSI Standard MC 1.1. The term "HP-IB"
  19. is also used to identify Hewlett-Packard instruments conforming with
  20. this standard.
  21. ** Standard-speed devices cannot be mixed on a high-speed bus.
  22. High-speed devices can be mixed on a standard-speed bus if high-speed
  23. cabling rules are observed.
  24. o Support of Command Set 80 protocol for CS/80-based disks and tapes
  25. o Parity check and Cyclic Redundancy Check-16 for error detection
  26. o Simple implementation of computer-controlled instrumentation and
  27.   peripheral systems
  28. o Selectable HP-IB controller or slave capabilities
  29. o Programmatically-enabled or -disabled parallel poll mode
  30. o Firmware-based self-test to help ensure interface integrity
  31.  
  32. [Figure 1 (HP-IB* Interface for HP 3000 Series 900 Computer Systems
  33.   diagram)  Caption: none]
  34.  
  35. HP-IB Capabilities
  36. The HP 27113A HP-IB Interface connects to the signal lines shown in
  37. Figure 1, acting as DEVICE A. Eight bidirectional data bus lines carry
  38. coded messages in bit-parallel, byte-serial form to/from other devices
  39. on the bus, with each byte transferred from one "talker" to one or more
  40. "listeners." Data is exchanged asynchronously using interface messages
  41. to setup, maintain, and terminate an orderly flow of device-dependent
  42. messages. Three handshake control lines control the transfer of each
  43. byte of coded data on the eight data lines. The five general interface
  44. management lines ensure an orderly flow of information within the
  45. HP-IB.
  46.  
  47. Functional Specifications
  48. Capacity
  49.    High-speed Devices per HP 27110B Interface:  Up to 8 with load
  50. resistors installed. Up to 14 without
  51.    Standard-speed HP-IB devices per interface:  Up to 14
  52.    Operating Modes
  53.       High-speed Mode:  Operation at data rates to 980 Kbytes/s
  54.       Standard-speed Mode:  Operation at data rates to 500 Kbytes/s
  55.    Note:  Attainable speed for a particular system is dependent on such
  56. factors as cabling length, type of external device, system level
  57. software, and number of devices. Higher transfer rates can be achieved
  58. when using less than maximum cable lengths and devices. Consult system
  59. documentation for further information or the HP-IB tutorial,
  60. P/N 5952-0156.
  61.       System Controller Mode:  A two-position switch enables HP 27113A
  62. operation as system controller or disables such operation.
  63.    Bus Characteristics
  64.       HP-IB Signal Lines:
  65.          DIO1  Data Input/Output 1
  66.          DIO2  Data Input/Output 2
  67.          DIO3  Data Input/Output 3
  68.          DIO4  Data Input/Output 4
  69.          DIO5  Data Input/Output 5
  70.          DIO6  Data Input/Output 6
  71.          DIO7  Data Input/Output 7
  72.          DIO8  Data Input/Output 8
  73.          DAV   Data Valid
  74.          NRFD  Not Ready for Data
  75.          NDAC  Not Data Accepted
  76.          IFC   Interface Clear
  77.          ATN   Attention
  78.          SRQ   Service Request
  79.          REN   Remote Enable
  80.          EOI   End or Identify
  81.    Logic Levels:  High >2.4 V; Low <0.5 V; all signals are low true
  82.    Supported HP-IB Functions:  C1-C5, SR1, RL2, PP1, DC1, SH1, AH1, T1,
  83. TE1, L1, LE1, DT1, E2. TE1 and LE1 require host system support.
  84.    Logic Levels, Line Drivers, Line Terminations, and Line Receivers:
  85. All characteristics conform to IEEE Standard 488-1978.
  86.    Maximum Cable Length for Standard Operation:  2 meters (6.5 ft) per
  87. device connected, with a 20-meter (65 ft) total length. The maximum
  88. number of devices is accommodated by interconnections using shorter
  89. than maximum cable length.
  90.    Maximum cable length for high-speed operation:  Interconnecting
  91. cable links should be as short as possible, with a maximum of 15 meters
  92. total length per system, and should have at least one equivalent
  93. resistive load per meter of cable (the high-speed resistor pack adds
  94. seven equivalent resistive loads).
  95.       Number        Maximum Total
  96.       of            Cable Length
  97.       Devices       <meters)
  98.       1                 6
  99.       2                 9
  100.       3                 10
  101.       4                 11
  102.       5                 12
  103.       6                 13
  104.       7                 14
  105.       8 (maximum)       15
  106.  
  107. No more than eight devices are allowed in the system. A maximum system
  108. would be composed of a System Controller, with its high-speed resistor
  109. pack, and eight peripherals. Load resistors may need to be repositioned
  110. on the interface card for high-speed operation. Refer to the
  111. installation manual.
  112.    Note:  For high- and low-speed cable length operation, refer to the
  113. installation manual (P/N 27113-90001).
  114.  
  115. Error Detection
  116. Data errors can be detected using Cyclic Redundancy Check-16 on all
  117. data messages sent or received. CRC-16 can be used if the other
  118. participating device supports CRC-16. CRC-16 is invoked by the system
  119. for each transaction. See system documentation for details. Interface
  120. message errors are detected using odd byte parity.
  121.  
  122. Diagnostic Support
  123. An interface resident self-test, initiated on reset, is provided in the
  124. firmware of the HP 27113A.
  125.  
  126. Electrical Specifications
  127.    Voltage   Current       Power
  128.              Dissipation
  129.    +5V       1.8A          9.0 watts
  130.    +12V      35 mA         0.42
  131.  
  132. Physical Characteristics
  133.    Size:  172.7 mm (6.80 in long by 172 mm (6.75 in) wide
  134.    Weight:  234 g (8.2 oz); 679 g (23.8 oz) with HP-IB cable
  135.    I/O Channel Interconnects:  80-pin connector, J1
  136.    Device Interconnects:  26-pin connector, J2
  137.  
  138. Environmental Characteristics
  139.    Operating Temperature:  0 degrees C to 55 degrees C (32 degrees F to
  140. 131 degrees F)
  141.    Operating Relative Humidity:  5% to 95% RH at 40 degrees C (104
  142. degrees F)
  143.    Operating Altitude:  4600 m (15,000 ft) maximum
  144.  
  145. Ordering Information
  146. The HP 27113A includes:
  147. 27113-60301 HP-IB Interface Card for HP 3000 Series 900
  148. 27113-63001 4-meter HP-IB Cable
  149. 27113-90001 Installation Manual for MPE/XL Systems
  150. 30070-00043 HP-IB Backplate
  151.    HP 27113A Option
  152.       001 Deletes manual
  153.       002 Firmware upgrade
  154.       003 Sliverspan adapter
  155.  
  156. From HP Networking Communications Specifications Guide,
  157.    5091-3821E, 9205, p 248
  158. Associated files:  la3821n8.gal, la3821n8.plt
  159. HP-IB* Interface for HP 3000 Series 900 Computer Systems, Technical
  160. Data